Area of Refuge Command Center Analog 1-116 Call Box System

Each 2400 Series Call Box, Command Center, and outside phone line connect directly into the RATH® Supervisor Board (2500__-SPRVSR). The 2500-__SPRVSR has a Communications Failure relay output that can be connected to an addressable fire alarm module or fire control panel.
If power supervision is needed, an additional purchase of the UPS Monitor (2500-UPSMONITOR), which includes a Power Failure relay output, is required.


RATH® Supervisor Board (2500__-SPRVSR
2500-__SPRVSR

Part Numbers/Dimensions: Dimensions:
  • 2500-12SPRVSR (12 Zone):
    • 3-1/2" H x 19-1/4" W x 6" D
  • 2500-16SPRVSR (16 Zone):
    • 3-1/2" H x 19-1/4" W x 6" D
  • 2500-28SPRVSR (28 Zone):
    • 7" H x 19-1/4" W x 6" D
  • 2500-36SPRVSR (36 Zone):
    • 7" H x 19-1/4" W x 6" D
  • 2500-56SPRVSR (56 Zone):
    • 10-1/2" H x 19-1/4" W x 6" D
  • 2500-76SPRVSR (76 Zone):
    • 14" H x 19-1/4" W x 6" D
  • 2500-96SPRVSR (96 Zone):
    • 14" H x 19-1/4" W x 6" D
  • To order without the UPS Monitor, add an “N” to the end of the model number (ex: 2500-12SPRVSRN)
  • Includes 2500-UPSMONITOR

Specifications:
  • Supervisor monitors remote Call Boxes and telephone lines
  • Provides a relay output when it does not detect a component of the system

Connections:
  • RJ11 connections to each Call Box and phone line, punch down terminal connections to Distribution Module

Power Requirements:
  • 12vdc (includes UL listed transformer that plugs into a 120vac backed up source or use RATH® model RP7700104 or RP7701500

Mounting:
  • Wall mounted swing out bracket
UPS Monitor 2500-UPSMONITOR
2500-UPSMONITOR



Dimensions: 5-1/4" H x 3-1/8" W x 2-5/8" D

Power Requirements:
  • 24vdc @ 28mA / 24vac @ 69mA
  • 120vac @ 45mA / 230vac @ 36mA per module position

Polarized Coil Input(s): DC control inputs only

Energized Indicator: One red LED per module position

Contact Ratings:
  • Resistive load: 7A @ 30vdc, 10A @ 125vac, 7A @ 250vac
  • Inductive load: .25 HP 125/250vac (N.C.), .33HP 125/250vac (N.O.)


Contact Construction: Dry form "C" DPDT per module position

Ambient Temperature:
  • 32ºF to 120ºF (0°C to 49°C) @ 93% RH (@32°C)
  • Non-Condensing / Non-Freezing


"/T" Versions:
  • 3.5" wide, low profile snap track provided with mounting screws


"/C" Versions:
  • Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom
  • Cover Material: MR-101, MR-201: plastic ABS 94V-0 ("/C" Grey, "/C/R" Red) MR-104, MR-204: CRS 18ga ("/C" Grey, "/C/R" Red)


Approvals:
"T" versions: UL Recognized Component (UL864, UOXX2)File #S3403, CSFM File #7300-1004:106 “C” versions: UL Listed (UL864, UOXX), CUL Listed (UL864, UOXX7) File #S3403, CSFM File #7300-1004:101, MEA File #73-92-E Vol.14 (MR-101, MR-104), Vol. 16 (MR-201, MR-204) “C/R” versions: UL Listed (UL864, UOXX), CUL Listed (UL864, UOXX7) File #S3403, CSFM File #7300-1004:101, MEA File #73-92-E Vol. 22




360° Supervision