800-451-1460
Command Centers

Command Centers

Area of Refuge Two-Way Communication 1-116 Call Box System

A code compliant Area of Refuge System requires a central control point where the Call Boxes call for emergency assistance.
The Command Center base stations provide a means of communication between stranded individuals, rescue personnel, and offsite parties.
System includes: Base Stations & Distribution Modules (Power Supply with battery backup sold separately)
Available in 3 mounting options (surface, flush and desk)
Command Center Surface or Flush Mount Cabinet
Surface or Flush Mount Cabinet
Command Center Desk Mount
Desk Mount
Command Center Distribution Modules
Distribution Modules


Part Numbers & Dimensions:
  • Surface Mount Cabinet:
    • Zone: 12 (2500-12RC) 16 (-16RC) 28 (-28RC) 36 (-36RC) 56 (-56XRC) 76 (-76XRC) 96 (-96XRC) 116 (-116XRC)
    • Dimensions:
      • 2500-12RC, 16RC = 15.14" H x 12" W x 6.19" D
      • 2500-28RC, 36RC, 56XRC, 76XRC, 96XRC, 116XRC = 21.03" H x 20.3" W x 5.19" D
  • Flush Mount Cabinet:
    • Zone: 12 (2500-12RCF) 16 (-16RCF) 28 (-28RCF) 36 (-36RCF) 56 (-56XRCF) 76 (-76XRCF) 96 (-96XRCF) 116 (-116XRCF)
    • Dimensions:
      • 2500-12RCF, 16RCF
        • Front Frame: 16.06" H x 14" W x 3.07" D
        • Back Box: 15.64" H x 12" W x 3" D
      • 2500-28RCF, 36RCF, 56XRCF, 76XRCF, 96XRCF, 116XRCF
        • Front Frame: 21.13" H x 25" W x 3.06" D
        • Back Box: 20.66" H x 23" W x 3" D
  • Desk Mount:
    • Zone: 12 (2500-12NC) 16 (-16NC) 28 (-28NC) 36 (-36NC) 56 (-56XNC) 76 (-76XNC) 96 (-96XNC) 116 (-116XNC)
  • Distribution Modules:
    • Dimensions:
      • 12-36 Zone System = 2.04" H x 17.28" W x 11.8" D
      • 56-116 Zone System = 6.83" H x 17.18" W x 8.9" D

Code Compliance:
  • International Building Code (IBC)
  • National Fire Protection Association (NFPA)
  • Americans Disabilities Act (ADA)

Power Requirements:
  • Command Center and Sub-Master Stations are powered from the Distribution Module
  • Command Center and Sub-Master to Distribution Module requires a single pair

Wiring Requirements:
  • Command Center and Sub-Master to Distribution Module requires a single pair
  • SmartPhones to Distribution Module requires a single pair

Phone Capabilities:
  • Calls wait in queue until previous call is disconnected and receive a message stating that an emergency call is in progress. When the prior call clears, the next phone in queue is connected
  • Includes handset and speaker phone for communication to Call Boxes
  • Works with either our 2100 or 2400 series models with a single pair back to the Distribution Module. The 2400 Series is powered from the Distribution Module and the 2100 Series is powered from 2500-PWR24U
  • LEDs indicate which Call Boxes have initiated a call
  • Rescue personnel can communicate with individual Call Boxes and outside party

Distribution Module Features:
  • Included with Command Center
  • Surface mount
  • Install on a wall or table top
  • Requires 120vac power with battery backup or RATH® Power Supply with battery backup
  • Single dedicated phone line or as an Intercom System

Additional Features:
  • Standard system allows for a Command Center and a single Sub-Master Station (contact RATH® for additional Sub-Masters)
  • Audible alert sounds when phones place a call until Command Center or Sub-Master Station joins conversation
  • Can be configured with the main Command Center and multiple Sub-Master Stations (available in desk, surface, or flush mount)

Specifications:
  • Design: Powder coated steel enclosure with twist lock closure
  • Mounting: Surface, flush, or desk mount
  • Warranty: 3 years

Downloads:

Command Centers