800-451-1460
IP Command Center

IP Command Center

Area of Refuge Two-Way Communication 1-128 Call Box System

A code compliant Area of Refuge System requires a central control point where the Call Boxes call for emergency assistance.
The IP Command Center base stations provide a means of communication between stranded individuals, rescue personnel, and offsite parties.
System includes: Base Stations & Distribution Modules (Power Supply with battery backup sold separately)
Available in 3 mounting options (surface, flush and desk)

IP Command Center Surface or Flush Mount Cabinet
Surface or Flush Mount Cabinet
IP Command Center Desk Mount
Desk Mount
IP Command Center Distribution Modules
Distribution Modules


Part Numbers & Dimensions:
  • Surface Mount Cabinet:
    • Zone: 10 (2500-10RCV) 16 (-16RCV) 32 (-32RCV) 48 (-48RCV) 64 (-64XRCV) 80 (-80XRCV) 96 (-96XRCV) 112 (-112XRCV) 128 (-128XRCV)
    • Dimensions:
      • 2500-10RCV, 16RCV = 15.14" H x 12" W x 6.19" D
      • 2500-32RCV, 48RCV, 64XRCV, 80XRCV, 96XRCV, 112XRCV, 128XRCV = 21.03" H x 20.3" W x 5.19" D
  • Flush Mount Cabinet:
    • Zone: 10 (2500-10RCFV) 16 (-16RCFV) 32 (-32RCFV) 48 (-48RCFV) 64 (-64XRCFV) 80 (-80XRCFV) 96 (-96XRCFV) 112 (-112XRCFV) 128 (-128XRCFV)
    • Dimensions:
      • 2500-10RCFV, 16RCFV
        • Front Frame: 16.06" H x 14" W x 3.07" D
        • Back Box: 15.64" H x 12" W x 3" D
      • 2500-32RCFV, 48RCFV, 64XRCFV, 80XRCFV, 96XRCFV, 112XRCFV, 128XRCFV
        • Front Frame: 21.13" H x 25" W x 3.06" D
        • Back Box: 20.66" H x 23" W x 3" D
  • Desk Mount:
    • Zone: 10 (2500-10NCV) 16 (-16NCV) 32 (-32NCV) 48 (-48NCV) 64 (-64XNCV) 80 (-80XNCV) 96 (-96XNCV) 112 (-112XNCV) 128 (-128XNCV)
  • Distribution Modules:
    • Dimensions:
      • 10-48 Zone System = 2.04" H x 17.28" W x 11.8" D
      • 64-128 Zone System = 6.83" H x 17.18" W x 8.9" D

Code Compliance:
  • International Building Code (IBC)
  • National Fire Protection Association (NFPA)
  • Americans Disabilities Act (ADA)

Power Requirements:
  • Command Center and Sub-Master Stations are powered from PoE

Wiring Requirements:
  • Command Center to Distribution Module: Single pair or via IP (contact RATH® for a quote on the IP version)

Phone Capabilities:
  • Calls wait in queue until previous call is disconnected and receive a message stating that an emergency call is in progress. When the prior call clears, the next phone in queue is connected.
  • Calls wait in queue until previous call is disconnected and receive a message stating that an emergency call is in progress. When the prior call clears, the next phone in queue is connected
  • Includes handset and speaker phone for communication to Call Boxes
  • Works with our model 2100 series IP Call Boxes. Connect back to Distribution Module via an Ethernet connection. Max 300 between network switches. IP Call Boxes require PoE at 802.3af.
  • LEDs indicate which Call Boxes have initiated a call
  • Rescue personnel can communicate with individual Call Boxes and outside party
  • Audible alert sounds when Call Boxes place a call until Command Center joins conversation

Distribution Module Features:
  • Included with Command Center
  • Surface mount
  • Install on a wall or table top
  • Requires 120vac power with battery backup or RATH® Power Supply with battery backup
  • Single dedicated phone line or as an Intercom System

Additional Features:
  • Can be configured with the main Command Center and multiple Sub-Master Stations (available in desk, surface, or flush mount)

Specifications:
  • Design: Powder coated steel enclosure with twist lock closure
  • Mounting: Surface, flush, or desk mount
  • Warranty: 2 years

Downloads:

IP Command Center